Frequency of data provision
Meter type |
Frequency of data provision |
Additional conditions |
AMR, GOL and smart meters |
Each working day |
Except weekends and public holidays |
MMR |
Monthly |
After data has been validated |
YMR |
Annually |
After data has been validated |
Communication method
- Shared via SFTP (Secure File Transfer Protocol).
- Pre-configuration and authentication credentials are required in order to access the data.
Data format
- Data is provided in the form of flat CSV files.
- For AMR, GOL, MMR and YMR meter, one file is provided for each EAN code.
- For smart meters, one file is provided for all EAN codes.
Example of a file for an AMR meter

- Column A: meter EAN code
- Column B: frequency of reading
- Column C: energy type
- Column D: identification register
- A+ or A-: active withdrawal or injection of energy
- I+ or I-: inductive withdrawal or injection of energy
- C- or C+: capacitive withdrawal or injection of energy
- Column E: date of measurement
- Column F: time slot of measurement (winter = UTC+01, summer = UTC+02)
- Column G: value of measurement
- Column H: unit of measurement
- Column I: quality code
- 01: value read automatically
- 02: estimated value
- 03: aucune valeur plausible disponible
- 04: no plausible value available
- 99: missing value
Example of a file for a smart meter

- Register : tarif (HI = day, LOW = night)
- Direction : Offtake (withdrawal) or Injection